Artificial climate box performance indicators

Artificial climate box performance indicators
Document.write('') artificial climate box document.write('') ​​is a collection of document.write('') light incubator document.write('') basic function, while increasing the control humidity, making artificial climate box Simulate environmental parameters more realistically. RTOP artificial climate box adopts advanced microcomputer programmable control mode, which can set multiple parameters including number of segments, temperature, humidity, illuminance and time. You only need to set the program before the program runs. The instrument will follow the set. The mode runs and automatically jumps without the need for a dedicated guard.
The artificial climate chamber is also suitable for seed germination culture, in which the function of the artificial climate chamber is equivalent to the document.write('') seed germination box document.write('') . Seed germination has higher requirements on temperature and moisture, and low demand for light, so we can set according to the growth characteristics of seeds. RTOP artificial climate box adopts PID output control, illuminance is adjustable in five levels, with power-down memory function; ultrasonic humidification, reliable humidification, high temperature control precision; reflective tempered coated glass, good thermal insulation performance, keeping the temperature inside the box stable; artificial The climate chamber is now used for performance testing of plant seed germination, cultivation and seedling, insects, small animal feeding, wood, building materials, etc. Let us look at the specific parameter settings of the artificial climate chamber.
The artificial climate chamber is different from the light incubator in that it can control three parameters of temperature, humidity and illuminance. The temperature parameters are: control range: 5-50 ° C (light off), 10-50 ° C (light on) (national standard 10-40 ° C), fluctuation: ± 0.5-1.0 ° C (test conditions are no load, room temperature 25±5°C), uniformity: ≤±1.0°C; humidity parameter: control range: 30%-95% RH, fluctuation: ±7% RH (relative humidity greater than 70% RH); illuminance parameter: rated Illuminance: 3000∽30000LX (according to the model), relative illuminance control range: five (20%, 40%, 60%, 80%, 100% rated illuminance); when the temperature rises, when 3 ° C rises to 40 ° C At less than 80 minutes, the temperature of 40 ° C is lowered to 10 ° C, which is less than 120 minutes, and the temperature of the cabinet can be adjusted to the user's demand in a quick time. The artificial climate chamber can be set up for 30 operating hours, each no longer than 24 hours.

Skin Infection

Skin Infection

Shandong Unovet Pharmaceutical Co.,Ltd. , https://www.unovetcn.com

Posted on