As a commonly used equipment in the production industry, heat shrink packaging machines are widely used in beverage, food, and daily necessities industries. Of course, a good heat shrink packaging machine also requires daily maintenance to ensure its normal operation.

1. Regularly lubricate the oil hole with the seat, the gear meshing position and the various moving parts with oil lubrication, once per shift;

2. When filling the heat shrink packaging machine with oil, do not drop the oil on the transmission belt to prevent the belt from prematurely paperless damage or slipping;

3, the use of heat shrink packaging machine: temperature -10 ° C ~ 50 ° C, relative humidity ≤ 85%, no corrosive gas in the surrounding air, no dust, no explosion hazard;

4. When the equipment is installed, it must have a reliable grounding device;

5. Keep the silicone strip and heating strip clean, and do not stick foreign matter, so as not to affect the sealing quality of the equipment;

6. The heat shrink packaging machine should be ventilated and energized during operation. When it stops, it should be shut off after power off.

Maintenance of the electrical part 1. The operator should always check whether the wire ends of the joints are loose. 2. The probes of the photoelectric switch and the proximity switch are dusty, which may cause malfunctions. Therefore, it should be checked and cleaned frequently. 3. Regularly use soft. Gauze 蘸Alcohol cleans the surface of the electric slip ring and removes the toner on the surface (Note: be sure to cut off the power when cleaning)

4. Non-professional management personnel shall not open the electrical part. The parameters or procedures of the inverter, microcomputer and other control components have been set. Please do not change it arbitrarily, otherwise the machine will be damaged.

The heat shrink machine is also in the following faults, the troubleshooting reference method is as follows:

1. There is no heating in the shrinkage chamber ● Poor contact of the heating switch, change the switch ● Indoor wire aging short circuit, change the wire ● The electric heating pipe head is not connected or the electric heating pipe is damaged ● The temperature control board is damaged, exchanged ● Potentiometer is bad, change 2 The conveyor network does not turn ● The conveyor switch fails, the exchange ● The speed control board is broken, the exchange is changed ● The potentiometer is bad, the exchange ● The transmission motor is damaged, the exchange is changed ● The conveying mechanism is stuck, the fault is eliminated after inspection 3. The hot air motor does not rotate ● The hot air switch is damaged , exchange ● motor damage, exchange